2027.0.0.422
Released on 11/1/2026.
New features
- The Reference files dialog has a check box to open the drawing file without loading the associated photogrammetric project or model
- The installer includes a code table in English
- The AI chat panel shows its texts in the interface language
- The .reference_files.json file of each drawing file can store the photogrammetric project and model, and Digi3D.AI loads them when the drawing file is opened
- The About dialog shows the program version
- The new version notice uses the theme colors
- Photogrammetric projects (.d3dprj) accept pairs of the RPC Satellite (stereoscopic) sensor, with automatic pair switching
- New GROUND_CURSOR command: draws around the cursor a circle with the given radius in ground units, in the drawing window and in the photogrammetric window
- The RPC Satellite (stereoscopic) sensor shows on the images the ground control points measured for the RPC block adjustment
- The RPC block adjustment panel shows the root mean square error, the mean and the maximum absolute value of each residual column
- When OK is clicked, the RPC block adjustment panel saves an adjustment report with the coordinate reference systems of the ground and of the RPCs
- BINTRAM, SPIT_LINES and SPLIT_VISIBLES_LINES add to the Tasks panel an error for each line they could not split, with the reason
- The New project dialog asks whether to overwrite the copied model when the new model would be saved to the same .d3d file
- If a photogrammetric model cannot be opened, the message shows the cause; for example, the name and path of the missing geoid grid
Fixes
- Compressing the drawing file and then redrawing closed the program if the file had deleted polygons with holes or deleted complexes
- In the aerial triangulation measurement, selecting a point with a thumbnail could close the program
- Opening a PointCloud model whose clouds could not be read showed «Bad optional access»; now the program reports that no cloud could be read
- Cancelling the preparation of an image showed an error message
- After changing the code table, the Python rules and quality controls of the previous table were still active
- Opening a file in a format without parameters (WMS, GeoJSON, IFC, WKT...) showed an empty import parameters dialog
- LOAD_F did not warn when no importer accepted the file extension
- The %ENTITY_*_ROUND_INT% macros truncated instead of rounding to the nearest integer
- Some startups failed while loading the Sentinel license generation library; now it is only loaded when needed
- Many English interface texts corrected, and controls resized so that texts are not cut off
- The horizontal and vertical coordinate reference system parameter dialogs closed the program
- .bind drawing files with a connection string could not be opened if their configuration had been saved with the interface in another language
- Fixed English interface texts that were truncated, untranslated or misspelled
- AREA, DRAW_PERIMETER and DRAW_PERIMETER_3D closed the program if Enter was pressed in the status bar after placing the text
- Adding geometries to a drawing file could close the program if the list of reference files had, before it, a file that is not drawn in the photogrammetric window, such as a raster, a WMS layer, a KML file or a point cloud
- Drawing a point with a symbol in the photogrammetric window closed the program if another reference file had been loaded after its drawing file
- In Python, the object returned by geographic_calculator became invalid and could close the program after loading a reference file or opening another drawing
- From the second iteration on, the RPC block adjustment did not honor the a priori precisions of the correction parameters and of the ground control points
- Absolute orientation failed from the third measured point on when the vertical reference system had a geoid model, such as EGM2008
- Digi3D.AI did not find the EGM2008 geoid grids with the _SE suffix; the installer creates links with the EPSG catalog name
- BINTRAM, SPIT_LINES and SPLIT_VISIBLES_LINES did not split any line when the drawing file rejected one of the pieces; now only the line of that piece stays unsplit
- When splitting lines, a back-and-forth piece [A, B, A] was left with two identical vertices and the drawing file rejected it
- The geographic calculator computed wrong distances, azimuths and areas in geographic systems whose angular unit is not the degree, such as NTF (Paris)
- The area of a polygon in a geographic system was larger than on the ellipsoid: 0.2 % for a 5° × 5° polygon at 40° latitude